Selection
Guide
Fiber Sensor
Amplifiers
FX-300
FX-100
Fibers
FT / FD / FR
FX-410
FX-311
FX-11A
FX-301-F
Other
Products
FIBER
SENSORS
FX-100
Fiber sensor
Ampilifi ers
Code setting function
Settings for “output operation”, “timer”, “emission
amount”, “emission frequency”, “ECO”, “external input”,
and “shift amount” are possible by selecting codes
discretionary.
The code setting function makes it possible to set the
output operation, timer operation, amount of light emitted,
frequency of light emitted, ECO setting, external input,
and amount of shift by selecting a code of one’s choice.
While in the RUN Mode, pressing and holding both
the ON key ( ) and OFF key ( ) simultaneously for 4
seconds will switch to the code setting function.
•
•
•
Quick setting function
Settings for “output operation”, “light-emitting amount”,
“timer”, and “emission frequency” are possible simply by
selecting a setting number.
The quick setting function makes it possible to set
the content of the SET Mode (output operation, timer
operation, amount of light emitted, and frequency of light
emitted) simply by selecting a setting number.
While in the RUN Mode, pressing and holding both
the ON key (
) and OFF key ( ) simultaneously for 2
seconds will switch to the quick setting function.
•
•
•
<Table of quick setting numbers>
No.
Output operation
Emission amount setting
Timer
D-ON OFF non
D-ON ON non
D-ON OFF ofd 10 ms
D-ON ON ofd 10 ms
D-ON OFF ofd 40 ms
D-ON ON ofd 40 ms
D-ON OFF ond 10 ms
D-ON ON ond 10 ms
D-ON OFF ond 40 ms
D-ON ON ond 40 ms
L-ON ON ond 40 ms
L-ON OFF ond 40 ms
L-ON ON ond 10 ms
L-ON OFF ond 10 ms
L-ON ON ofd 40 ms
L-ON OFF ofd 40 ms
L-ON ON ofd 10 ms
L-ON OFF ofd 10 ms
L-ON ON non
L-ON OFF non
Others
Do not use during the initial transient time (0.5 sec.) after
the power supply is switched on.
EEPROM is adopted to this product. It is not possible to
conduct teaching 100 thousand times or more, because
of the EEPROM’s lifetime.
•
•
PRECAUTIONS FOR PROPER USE
Refer to p.986~ for general precautions, and to the “Operation Guide” or “SUNX website”
(http://www.sunx.com) for details pertaining to operating instructions for the amplifi er.
<Code table>
Code
1st digit 2nd digit 3rd digit
4th digit
Output
operation
Timer
(Note5)
Emission
amount
setting
Emission
Frequency
ECO
Extemal
input
Shift
(Note5)
FX-101□ FX-102□
D-on
non
OFF
01
OFF
E_oF 5 %
ond 10 ms
12
Limit [+]
10 %
ond 40 ms
23
Limit [–]
15 %
ofd 10 ms
3 4 Auto 20 %
ofd 40 ms
ON
0 1 Eco 25 %
L-on
non 1 2
ON
E_oF 30 %
ond 10 ms
23
Limit [+]
35 %
ond 40 ms
34
Limit [–]
40 %
ofd 10 ms
Auto 45 %
ofd 40 ms
Eco 50 %
Notes: 1) When the present setting is out of the code setting range, “
” is
shown.
When “
” is selected, the set content of the digit is not changed.
2) The factory setting is “
”.