MULTIPROX READER INSTALLATION
Model # 5385AGS00 (Side Mount)
Model # 5385AGB00 (Back Mount)
The MultiProx Reader subsystem is used in conjuction with
the MultiProx Controller to retrofit existing Schlage/
Westinghouse System Sensors. The following instructions
will explain the installation procedure for the MultiProx
Reader. The instructions include these sections:
Important Installation Guidelines
1. The MultiProx Reader must be located a minimum of 6 inches away from electrical wiring, conduit, metal wall studs or metal pipes
from the back.
2. The MultiProx Reader must be located a minimum of 2 inches (5.08cm), on all sides, away from any metal objects including rebar,
metal mesh, sheet metal, or metal beams.
3. Mounting the MultiProx Reader in an enclosure is acceptable, provided that a minimum of 3 inches (7.62cm) clearance is main-
tained on all sides (no metal on the front).
4. Insulate all cable connectors with electrical tape or shrink tubing so contact is not made with any metal or conductive material.
5. The MultiProx Reader should not be mounted within 6 feet of any monitors (VDTs or CRTs). The scan frequencies of most monitors
may interfere with the signal received from the access control cards. Motors and electronic devices generate RF noise that may
interfere with the reception of the signal from an access control card.
Parts List (Included) Quantity
1) MultiProx Reader (p/n 5385AGS or B) 1
2) Installation Manual 1
3) Label for front cover- HID logo 1
4) Terminal Connector 1
Not Included
Parts Recommended
1) Cable, Coax - RG6 or SE 9284 A/R
1000ft Maximum
2) Electrical tape or shrink tubing A/R
Parts Recommended (If this is not a Retrofit)
1) F-56 crimp-on connectors 2
2) Crimping tool 1
INSTALLATION REQUIREMENTS
MultiProx System Layout Diagram
Important Installation Guidelines
MultiProx Reader Installation
Mounting Instructions: Retrofitting an existing Sensor
Connecting the Reader Cable to the MultiProx Controller
Configuring the DIP Switch Settings on the MultiProx Controller
Specifications for the MultiProx Reader
MULTIPROX CONTROLLER
ACCESS
CONTROL
PANEL
ACCESS
CONTROL
SYSTEM HOST
HSM
M
ULTIPROX READERS
WIEGAND & RELAY OUTPUTS
READER 1 WIEGAND DATA
READER 8 WIEGAND DATA
HSM 1 RELAY OUTPUTS
HSM 8 RELAY OUTPUTS
TBW1
TBW8
TBR1
TBR8
M
AXIMUM - 8 READER CHANNELS
READER CHANNEL 1
R
EADER CHANNEL 8
MultiProx System Layout Diagram
KEY
EXISTING RG/6 COAX
ALPHA 1295 OR EQUIVALENT PER CHANNEL
ALPHA 1292 OR EQUIVALENT PER OUTPUT
UP TO - 8 RELAYS &
8 W
IEGAND CONNECTORS
Vista de pagina 0
1 2

Indice de contenidos

Pagina 1 - INSTALLATION REQUIREMENTS

MULTIPROX READER INSTALLATIONModel # 5385AGS00 (Side Mount)Model # 5385AGB00 (Back Mount)The MultiProx Reader subsystem is used in conjuction witht

Pagina 2 - PROX CONTROLLER

MultiProx Reader Installation Mounting Instructions:Retrofitting an existing Sensor1. Locate the existing Schlage/Westinghouse Sensor.Determine th