Vista de pagina 119
7-32
CONTINUE
Yes
Check the following parts
ZD6G1, C6G1, C6G2, F671,
Q671, R6G1, D6G2, C623,
Q623, D623, D625, D673,
D6E1, IC621, IC671, L6E1,
PC621, ZD622, T601
All outputs are 0V. And when the
power switch turn on, the voltage
of both ends of C623 increase
until approx 10V, and become 0V
momentarily.
Yes
Check the following parts
IC621,C622,C609,C610,
C621,R625,IC651
Fuse F6T1 is broken.
No
Yes
Check the following parts
D602, R634, R635, IC621
IC651
All outputs are 0V. And when the
power switch turn on, the voltage
of both ends of C623 is within the
range of 0V to 10V.
No
Yes
Check the following parts
C652,C653,C654,D6L1,
D6M1,R655,R663,ZD651,
Q651,Q652,Q653,IC651,
IC652,T651
+20V and -20V output is 0V.
And when the power switch turn on,
the voltage of both ends of C651
increase until approx 13V, and become
0V momentarily.
No