Revision 1.9 - 22 -
5.4.1
Platform storage Up-stops
With gate power wiring in place and fully functional, place gate and platform in final storage position for
installation of up stops.
- The up stop assembly (x2) and the steel right angle piece (x2) are included with every gate.
Figure 15 Installation of up-stops
- Up Stops MUST be installed to avoid damage to platform when travelling down the road
- The up stop must be mounted high enough so that they do not make contact with the mainframe tube.
- Rubber bumper should make contact with Alum Tip section 1-1/2“ below steel sliding tube (see Figure 14)
- Place the channel so that it is connected to cross members and buck plate, to get the most stability
- The up stops must be mounted rearward enough so that they do not make contact with a tube mounted
aux battery box when the gate is slid out (Figure 15 right picutre)
- The main pin and lift cylinder hoses must clear the up stop when the gate is slid out (Figure 15 left picutre)
Figure 16 Up-stop setup for travel position