Caple C602E Manual de instalación Pagina 37

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 40
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 36
Revision 1.9 - 37 -
7.1
Lubrication
Location of Grease Zerks (7 on each side, 14 total)
Oil level in the power pack tank (see marking inside of power pack reservoir)
Platform hinges, Slide Rails and optional Cart Stops (use WD-40 spray for lubrication)
Open platform and raise lift gate to bed level
Remove red caps, apply grease until grease begins to flow from bushing ends
Lower platform to ground and repeat
Cycle platform open and closed several times and grease again
Wipe excess grease from joints and replace ALL red caps
4 zerks:
- 1 cylinder
- 1 Lift arm
- 1 Parallel arm
- 1 Swing fixture
3 zerks:
- 1 cylinder
- 1 Lift arm
- 1 Parallel arm
3 zerks:
- 1 cylinder
- 1 Lift arm
- 1 Parallel arm
4 zerks:
- 1 cylinder
- 1 Lift arm
- 1 Parallel arm
- 1 Swing fixture
Oil reservoir
inside main tube.
Pull out tray to
check and refill
oil.
Vista de pagina 36
1 2 ... 32 33 34 35 36 37 38 39 40

Comentarios a estos manuales

Sin comentarios