HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier MN/HPOD.IOM
Appendix B Revision 8
B–9
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codesi.e., ASCII codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to
query
(Target to
Controller)
Set Backup
Offset
SBO=
7 bytes,
numerical
Command or Query.
Set or query the adjusted attenuation level, in 0.25 dB increments, in a 1:2 redundancy system
so power is equal between the online and offline units when a switchover occurs. In the form
#,xx.xx where:
# = 1 or 2
xx.xx = level, in 0.25 dB increments
Examples: SBO=1,02.00’cr’ or SBO=2,02.50’cr’
SBO=
SBO?
SBO*
SBO?
SBO=#,xx.xx
(See Description of
Arguments for
details)