Caple C804C Especificaciones Pagina 141

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 150
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 140
HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier MN/HPOD.IOM
Appendix B Revision 8
B–11
B.4.2 Operation
Task Procedure
1 Set both units to “Auto” redundancy mode by sending them RAM=1 command.
2
Establish the current online status by sending each unit an ONL? query. Note one unit should return
ONL=1 (online), and one unit should return ONL=0 (offline)
3 Fail the unit that reported ONL=1. The switch should throw. Restore the unit
4
Repeat the ONL? query to both units. The unit that was failed in step 2 should now report ONL=0 and the
other should report ONL=1. Fail this unit and confirm the switch transitions.
5 Put the system in “Manual” mode by sending RAM=0 commands to both units.
6
The “SSW” command will force the switch to point to the selected unit. For example, an “SSW=1”
command will force the switch to point to SSPA 1 no matter which SSPA the command was issued to.
Ensure either unit can throw the switch in both directions by sending the following commands:
<1/SSW=1 (the switch may or may not transition)
<1/SSW=2 (the switch should transition)
<1/SSW=1 (the switch should transition)
<2/SSW=2 (the switch should transition)
<2/SSW=1 (the switch should transition)
Vista de pagina 140
1 2 ... 136 137 138 139 140 141 142 143 144 145 146 ... 149 150

Comentarios a estos manuales

Sin comentarios