HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier MN/HPOD.IOM
Serial-Based Remote Product Management Revision 8
5–12
Parameter
Type
(Instruction
Number of
Arguments
Description of Arguments
Response to
Command
(Instruction
Response to Query
Power FET
Current Status
depending on
the number of
FETs installed in
the amplifier
Reports concise version of RFS. response is comma delimited in the form xxx,xxx,x.x,x.x,……….,x.x
(See RFS Description
of Arguments)
Identification
alphanumeric
Set User-defined string to identify or name the unit or station. The CID is a 24-byte field of data that is
entered as one line, but it will be read back from the unit as two 12-byte lines of data.
Examples:
<1/CID= Station #001--HPOD #01--’cr’
>0001/CID=
<1/CID?’cr’
>0001/CID=’cr’
Station #001’cr’
CID?
(See Description of
Arguments)
Maintenance
Status
alphanumeric
Reports the concise version of RMS. The response is comma delimited in the form
aaa.a,bbb.b,ccc.c,ddd.d,eee.e, fff.f,ggg.g,hhh.h,iii.i,jjj.j,kkk.k,lll.l,mmm.m,nnn.n,’cr’’lf’ where:
aaa.a = +24V Power Supply
bbb.b = +15V Power Supply
ccc.c = +10V-1 Power Supply
ddd.d = +10V-2 Power Supply
eee.e = +7.5V Power Supply
fff.f = +5V Power Supply
ggg.g = -5V Power Supply
hhh.h = Fan #1 speed (in percent)
iii.i = Fan #2 speed (in percent)
jjj.j = Amplifier temperature in deg. C
kkk.k = Amplifier 10V1
lll.l = Amplifier 10V2
mmm.m=Forward RF output power, in dBm
Note: nnn.n will appear for Ref Voltage if Reference Oscillator Module is installed.
(See Description of
Arguments)
Redundancy
Amp
value of 0,1
Permits configuration of the redundancy amplifier mode in 1:1 and 1:2 redundancy systems, in the form x,
where:
0 = disabled – the unit’s amp state behaves as in previous firmware versions (Default)
1 = enabled – the unit’s amp state should follow its mute value, such that the offline unit will turn off its
amplier; if it becomes the online unit, then its amplifier will turn on. This affects all units in the redundancy
system.
Note: The same CRA value should be sent to all units in the redundancy system.
CRA?
(See Description of
Arguments)