HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier MN/HPOD.IOM
Serial-Based Remote Product Management Revision 8
5–18
Parameter
Type
(Instruction
Number of
Arguments
Description of Arguments
Response to
Command
(Instruction
Response to Query
Status
value of 0,1
Returns the condition of the summary fault relay where:
0 = Not Faulted (SumFLT_COM J6 pin K is connected to SumFLT_NO J6 pin L, and SumFLT_NC J6 pin
M is open)
1 = Faulted (SumFLT_COM J6 pin K is connected to SumFLT_NC J6 pin M, and SumFLT_NO J6 pin L is
open)
Example: <1/SFS?
>0001/SFS=0’cr’’lf’
(See Description of
Arguments)
Address
numeric
Set Physical Address in the form xxxx, where:
xxxx = address between 0001 to 9999, resolution 0001
SPA?
(See Description of
numeric
Sets or returns the RTC time in the form hhmmss, where:
hh = hours, between 00 and 23;
mm = minutes, between 00 and 59,
ss = seconds, between 00 and 59
Example:(time = 23 hours, 12 minutes and 59 seconds since midnight.):
<1/TIM=231259’cr’
TIM?
TIM*
(See Description of
Arguments)
Number of
unread
Stored Alarms
numeric,
00 to 99
Returns the number of stored events that remain unread in the alarm log, in the form xx, where:
Xx = A maximum of 99 events may be stored in the alarm log.
Example:
<1/TNA? ’cr’
(See Description of
Arguments)
change
value of 0,1
Indicates if there has been a change in the terminal status since the last time the command was given. A
value of 0 indicates no status change, and a value of 1 indicates there has been a terminal status change.
Example:
<1/TSC?’cr’
>0001/TSC=0’cr’’lf’
(See Description of
Arguments)
Current Active software image, in the form x, where:
1=Bulk Image # 1 currently active
2=Bulk Image # 2 currently active
Example: IMG=1 (which is Image #1 active)
IMG?
IMG*
IMG#
(See Description of
Arguments)
Comentarios a estos manuales